6.2.4.4 Pset_DistributionChamberElementTypeInspectionChamber
6.2.4.4.1 Semantic definition
Chamber constructed on a drain, sewer or pipeline and with a removable cover, that permits visible inspection.
6.2.4.4.2 Applicable entities
- IfcDistributionChamberElement/INSPECTIONCHAMBER
- IfcDistributionChamberElementType/INSPECTIONCHAMBER
6.2.4.4.3 Properties
Name | Property Type | Data Type | Description | |
---|---|---|---|---|
ChamberLengthOrRadius | IfcPropertySingleValue | IfcPositiveLengthMeasure |
Length or, in the event of the shape being circular in plan, the radius of the chamber. |
|
ChamberWidth | IfcPropertySingleValue | IfcPositiveLengthMeasure |
Width, in the event of the shape being non circular in plan. |
|
InspectionChamberInvertLevel | IfcPropertySingleValue | IfcLengthMeasure |
Level of the lowest part of the cross section as measured from ground level. |
|
SoffitLevel | IfcPropertySingleValue | IfcLengthMeasure |
Level of the highest internal part of the cross section as measured from ground level. |
|
WallMaterial | IfcPropertyReferenceValue | IfcMaterialDefinition |
The material from which the wall of the chamber is constructed. NOTE: It is assumed that chamber walls will be constructed of a single material. |
|
WallThickness | IfcPropertySingleValue | IfcPositiveLengthMeasure |
The thickness of the wall construction. NOTE: It is assumed that walls will be constructed at a single thickness. |
|
BaseMaterial | IfcPropertyReferenceValue | IfcMaterialDefinition |
The material from which the base of the chamber is constructed. NOTE: It is assumed that chamber base will be constructed of a single material. |
|
BaseThickness | IfcPropertySingleValue | IfcPositiveLengthMeasure |
The thickness of the base construction, assumed to be constructed at a single thickness. |
|
WithBackdrop | IfcPropertySingleValue | IfcBoolean |
Indicates whether the chamber has a backdrop or tumbling bay (TRUE) or not (FALSE). |
|
AccessCoverMaterial | IfcPropertyReferenceValue | IfcMaterialDefinition |
The material from which the access cover to the chamber is constructed. NOTE: It is assumed that chamber walls will be constructed of a single material. |
|
AccessLengthOrRadius | IfcPropertySingleValue | IfcPositiveLengthMeasure |
The length of the chamber access cover or, where the plan shape of the cover is circular, the radius. |
|
AccessWidth | IfcPropertySingleValue | IfcPositiveLengthMeasure |
The width of the chamber access cover where the plan shape of the cover is not circular. |
|
AccessCoverLoadRating | IfcPropertySingleValue | IfcText |
The load rating of the access cover (which may be a value or an alphanumerically defined class rating). |