IFC 4.3.2.20240904 (IFC4X3_ADD2) under development

7.8.4.8 Pset_CableCarrierSegmentTypeDropper

7.8.4.8.1 Semantic definition

Properties that are applicable to a type or an occurrence of dropper.

7.8.4.8.2 Applicable entities

7.8.4.8.3 Properties

Name Property Type Data Type Description
CurrentCarryingCapacity IfcPropertySingleValue IfcElectricCurrentMeasure

Maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value. Based on IEC60826-11-13. NOTE: The temperature specified value is maximum Design Ambient Temperature.

TensileStrength IfcPropertySingleValue IfcPressureMeasure

Indicates the ability to withstand breakage apart under applied force.

AssemblyInstruction IfcPropertyReferenceValue IfcExternalReference

Instructions to describe how the system / equipment / facility is assembled.

IsRigid IfcPropertySingleValue IfcBoolean

Indication of whether the conduit is rigid (= TRUE) or flexible (= FALSE).

UltimateTensileStrength IfcPropertySingleValue IfcForceMeasure

Indicates the maximum stress that a material or element can withstand before breaking while being stretched or pulled.

IsAdjustable IfcPropertySingleValue IfcBoolean

Indicates whether the element is adjustable or not.

IsCurrentCarrying IfcPropertySingleValue IfcBoolean

To indicate whether the current will go through the dropper.

NominalLoad IfcPropertySingleValue IfcForceMeasure

The nominal load that a component can support.

Table 7.8.4.8.A

Edit on Github


Is this page difficult to understand? Let us know!

7.8.4.8.4 Changelog

7.8.4.8.4.1 IFC4.3_DEV_c85b862

  • New resource