IFC 4.3.2.20241204 (IFC4X3_ADD2) under development

7.5.4.63 Pset_FlowMeterTypeCommon

7.5.4.63.1 Semantic definition

Common attributes of a flow meter type

7.5.4.63.2 Applicable entities

7.5.4.63.3 Properties

Name Property Type Data Type Description
Reference IfcPropertySingleValue IfcIdentifier

Reference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used.

Status IfcPropertyEnumeratedValue PEnum_ElementStatus

Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).

ReadOutType IfcPropertyEnumeratedValue PEnum_MeterReadOutType

Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer.

RemoteReading IfcPropertySingleValue IfcBoolean

Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE).

Table 7.5.4.63.A

Edit on Github


Is this page difficult to understand? Let us know!

7.5.4.63.4 Changelog

7.5.4.63.4.1 IFC4

7.5.4.63.4.2 IFC4.3_DEV_7e95fe8