7.8.4.82 Pset_MechanicalFastenerTypeRailJoint
7.8.4.82.1 Semantic definition
Properties common to a rail joint of a railway track system. The property set can be used by the predefined type RAILJOINT of IfcMechanicalFastener.
7.8.4.82.2 Applicable entities
- IfcMechanicalFastener/RAILJOINT
- IfcMechanicalFastenerType/RAILJOINT
7.8.4.82.3 Properties
Name | Property Type | Data Type | Description | |
---|---|---|---|---|
SleeperArrangement | IfcPropertyEnumeratedValue | PEnum_SleeperArrangement |
Define the rail joint sleeper method of assembly ("twin sleeper" type or "between sleepers" type). |
|
IsCWRJoint | IfcPropertySingleValue | IfcBoolean |
Indicates if the rail joint is associated to a continuous welded rail. |
|
IsJointInsulated | IfcPropertySingleValue | IfcBoolean |
Indicates if the rail joint is insulated. |
|
IsLiftingBracketConnection | IfcPropertySingleValue | IfcBoolean |
Indicates if the connection is between two different heights (TRUE) or not (FALSE). |
|
NumberOfScrews | IfcPropertySingleValue | IfcCountMeasure |
Number of screws/bolts/connections. |
|
RailGap | IfcPropertySingleValue | IfcPositiveLengthMeasure |
The gap between the rail profiles. |
|
IsJointControlEquipment | IfcPropertySingleValue | IfcBoolean |
Indicates whether security equipment is checking the mechanical functionality of the rail joint. |
|
AssemblyPlace | IfcPropertyEnumeratedValue | PEnum_AssemblyPlace |
Enumeration defining where the assembly is intended to take place, either in a factory, other offsite location or on the building site. |