The IfcWasteTerminalTypeEnum defines the range of different types of waste terminal that can be specified.
7.6.2.5.2 Type values
Type
Description
FLOORTRAP
Pipe fitting, set into the floor, that retains liquid to prevent the passage of foul air
FLOORWASTE
Pipe fitting, set into the floor, that collects waste water and discharges it to a separate trap.
GULLYSUMP
Pipe fitting or assembly of fittings to receive surface water or waste water, fitted with a grating or sealed cover.
GULLYTRAP
Pipe fitting or assembly of fittings that receives surface water or waste water; fitted with a grating or sealed cover that discharges water through a trap.
ROOFDRAIN
Pipe fitting, set into the roof, that collects rainwater for discharge into the rainwater system.
WASTEDISPOSALUNIT
Electrically operated device that reduces kitchen or other waste into fragments small enough to be flushed into a drainage system.
WASTETRAP
Pipe fitting, set adjacent to a sanitary terminal, that retains liquid to prevent the passage of foul air.
USERDEFINED
User-defined type.
NOTDEFINED
Undefined type.
Table 7.6.2.5.A
7.6.2.5.3 Formal representation
TYPE IfcWasteTerminalTypeEnum = ENUMERATION OF
(FLOORTRAP
,FLOORWASTE
,GULLYSUMP
,GULLYTRAP
,ROOFDRAIN
,WASTEDISPOSALUNIT
,WASTETRAP
,USERDEFINED
,NOTDEFINED);
END_TYPE;