IFC 4.3.2.20240904 (IFC4X3_ADD2) under development

7.6.2.5 IfcWasteTerminalTypeEnum

7.6.2.5.1 Semantic definition

The IfcWasteTerminalTypeEnum defines the range of different types of waste terminal that can be specified.

7.6.2.5.2 Type values

Type Description
FLOORTRAP

Pipe fitting, set into the floor, that retains liquid to prevent the passage of foul air

FLOORWASTE

Pipe fitting, set into the floor, that collects waste water and discharges it to a separate trap.

GULLYSUMP

Pipe fitting or assembly of fittings to receive surface water or waste water, fitted with a grating or sealed cover.

GULLYTRAP

Pipe fitting or assembly of fittings that receives surface water or waste water; fitted with a grating or sealed cover that discharges water through a trap.

ROOFDRAIN

Pipe fitting, set into the roof, that collects rainwater for discharge into the rainwater system.

WASTEDISPOSALUNIT

Electrically operated device that reduces kitchen or other waste into fragments small enough to be flushed into a drainage system.

WASTETRAP

Pipe fitting, set adjacent to a sanitary terminal, that retains liquid to prevent the passage of foul air.

USERDEFINED

User-defined type.

NOTDEFINED

Undefined type.

Table 7.6.2.5.A

7.6.2.5.3 Formal representation

TYPE IfcWasteTerminalTypeEnum = ENUMERATION OF
	(FLOORTRAP
	,FLOORWASTE
	,GULLYSUMP
	,GULLYTRAP
	,ROOFDRAIN
	,WASTEDISPOSALUNIT
	,WASTETRAP
	,USERDEFINED
	,NOTDEFINED);
END_TYPE;

7.6.2.5.4 References

Edit on Github


Is this page difficult to understand? Let us know!

7.6.2.5.5 Changelog

7.6.2.5.5.1 IFC4

  • item, GREASEINTERCEPTOR
  • item, OILINTERCEPTOR
  • item, PETROLINTERCEPTOR