IFC 4.3.2.20240904 (IFC4X3_ADD2) under development

7.8.4.4 Pset_BalanceWeightTensionerDesignCriteria

7.8.4.4.1 Semantic definition

Properties of a weight tensioner. The property set can be used by the predefined type TENSIONINGEQUIPMENT of IfcDiscreteAccessory.

7.8.4.4.2 Applicable entities

7.8.4.4.3 Properties

Name Property Type Data Type Description
ReferenceDistanceRopeToPulley IfcPropertyTableValue IfcPositiveLengthMeasure/IfcThermodynamicTemperatureMeasure

The reference design criteria for distance from the end of the rope to the fixed pulley.It defines the nominal distance in relation to temperature.

ReferenceDistanceTensionerToGround IfcPropertyTableValue IfcPositiveLengthMeasure/IfcThermodynamicTemperatureMeasure

The reference design criteria distance from the last tensioner to the ground or the base surface (B value). It defines the nominal distance in relation to temperature.

Table 7.8.4.4.A

Edit on Github


Is this page difficult to understand? Let us know!

7.8.4.4.4 Changelog

7.8.4.4.4.1 IFC4.3_DEV_c85b862

  • New resource