7.11.4.7 Pset_ReinforcementBarCountOfIndependentFooting
7.11.4.7.1 Semantic definition
Reinforcement Concrete parameter [ST-2]: The amount number information of reinforcement bar with the independent footing. The X and Y direction are based on the local coordinate system of building storey. The X and Y direction of the reinforcement bar are parallel to the X and Y axis of the IfcBuildingStorey's local coordinate system, respectively.
7.11.4.7.2 Applicable entities
7.11.4.7.3 Properties
Name | Property Type | Data Type | Description | |
---|---|---|---|---|
Description | IfcPropertySingleValue | IfcText |
The Description of the object. |
|
Reference | IfcPropertySingleValue | IfcLabel |
Reference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used. A descriptive label for the general reinforcement type. |
|
XDirectionLowerBarCount | IfcPropertySingleValue | IfcCountMeasure |
The number of bars with X direction lower bar. |
|
YDirectionLowerBarCount | IfcPropertySingleValue | IfcCountMeasure |
The number of bars with Y direction lower bar. |
|
XDirectionUpperBarCount | IfcPropertySingleValue | IfcCountMeasure |
The number of bars with X direction upper bar. |
|
YDirectionUpperBarCount | IfcPropertySingleValue | IfcCountMeasure |
The number of bars with Y direction upper bar. |