IFC 4.3.2.20240904 (IFC4X3_ADD2) under development

7.11.4.7 Pset_ReinforcementBarCountOfIndependentFooting

7.11.4.7.1 Semantic definition

Reinforcement Concrete parameter [ST-2]: The amount number information of reinforcement bar with the independent footing. The X and Y direction are based on the local coordinate system of building storey. The X and Y direction of the reinforcement bar are parallel to the X and Y axis of the IfcBuildingStorey's local coordinate system, respectively.

7.11.4.7.2 Applicable entities

7.11.4.7.3 Properties

Name Property Type Data Type Description
Description IfcPropertySingleValue IfcText

The Description of the object.

Reference IfcPropertySingleValue IfcLabel

Reference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used.

A descriptive label for the general reinforcement type.

XDirectionLowerBarCount IfcPropertySingleValue IfcCountMeasure

The number of bars with X direction lower bar.

YDirectionLowerBarCount IfcPropertySingleValue IfcCountMeasure

The number of bars with Y direction lower bar.

XDirectionUpperBarCount IfcPropertySingleValue IfcCountMeasure

The number of bars with X direction upper bar.

YDirectionUpperBarCount IfcPropertySingleValue IfcCountMeasure

The number of bars with Y direction upper bar.

Table 7.11.4.7.A

Edit on Github


Is this page difficult to understand? Let us know!

7.11.4.7.4 Changelog

7.11.4.7.4.1 IFC4.3_DEV_c85b862