7.6.4.20 Pset_WasteTerminalTypeFloorWaste
7.6.4.20.1 Semantic definition
Pipe fitting, set into the floor, that collects waste water and discharges it to a separate trap.
7.6.4.20.2 Applicable entities
- IfcWasteTerminal/FLOORWASTE
- IfcWasteTerminalType/FLOORWASTE
7.6.4.20.3 Properties
Name | Property Type | Data Type | Description | |
---|---|---|---|---|
NominalBodyLength | IfcPropertySingleValue | IfcPositiveLengthMeasure |
Nominal or quoted length measured along the x-axis of the local coordinate system of the object. |
|
NominalBodyWidth | IfcPropertySingleValue | IfcPositiveLengthMeasure |
Nominal or quoted length, measured along the y-axis of the local coordinate system of the object. |
|
NominalBodyDepth | IfcPropertySingleValue | IfcPositiveLengthMeasure |
Nominal or quoted length measured along the z-axis of the local coordinate system of the object. |
|
OutletConnectionSize | IfcPropertySingleValue | IfcPositiveLengthMeasure |
Size of the outlet connection from the object. |
|
CoverLength | IfcPropertySingleValue | IfcPositiveLengthMeasure |
The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the object. |
|
CoverWidth | IfcPropertySingleValue | IfcPositiveLengthMeasure |
The length measured along the y-axis in the local coordinate system of the cover of the object. |