8.19.3.6 IfcFailureConnectionCondition
8.19.3.6.1 Semantic definition
Defines forces at which a support or connection fails.
Applicability:
- Point supports and connections.
8.19.3.6.2 Entity inheritance
8.19.3.6.3 Attributes
# | Attribute | Type | Description |
---|---|---|---|
IfcStructuralConnectionCondition (1) | |||
1 | Name | OPTIONAL IfcLabel |
Optionally defines a name for this connection condition. |
Click to show 1 hidden inherited attributes Click to hide 1 inherited attributes | |||
IfcFailureConnectionCondition (6) | |||
2 | TensionFailureX | OPTIONAL IfcForceMeasure |
Tension force in x-direction leading to failure of the connection. |
3 | TensionFailureY | OPTIONAL IfcForceMeasure |
Tension force in y-direction leading to failure of the connection. |
4 | TensionFailureZ | OPTIONAL IfcForceMeasure |
Tension force in z-direction leading to failure of the connection. |
5 | CompressionFailureX | OPTIONAL IfcForceMeasure |
Compression force in x-direction leading to failure of the connection. |
6 | CompressionFailureY | OPTIONAL IfcForceMeasure |
Compression force in y-direction leading to failure of the connection. |
7 | CompressionFailureZ | OPTIONAL IfcForceMeasure |
Compression force in z-direction leading to failure of the connection. |
8.19.3.6.4 Formal representation
ENTITY IfcFailureConnectionCondition
SUBTYPE OF (IfcStructuralConnectionCondition);
TensionFailureX : OPTIONAL IfcForceMeasure;
TensionFailureY : OPTIONAL IfcForceMeasure;
TensionFailureZ : OPTIONAL IfcForceMeasure;
CompressionFailureX : OPTIONAL IfcForceMeasure;
CompressionFailureY : OPTIONAL IfcForceMeasure;
CompressionFailureZ : OPTIONAL IfcForceMeasure;
END_ENTITY;