IFC 4.3.2.20240904 (IFC4X3_ADD2) under development

8.19.3.6 IfcFailureConnectionCondition

8.19.3.6.1 Semantic definition

Defines forces at which a support or connection fails.

Applicability:

  • Point supports and connections.

8.19.3.6.2 Entity inheritance

8.19.3.6.3 Attributes

# Attribute Type Description
IfcStructuralConnectionCondition (1)
1 Name OPTIONAL IfcLabel

Optionally defines a name for this connection condition.

Click to show 1 hidden inherited attributes Click to hide 1 inherited attributes
IfcFailureConnectionCondition (6)
2 TensionFailureX OPTIONAL IfcForceMeasure

Tension force in x-direction leading to failure of the connection.

3 TensionFailureY OPTIONAL IfcForceMeasure

Tension force in y-direction leading to failure of the connection.

4 TensionFailureZ OPTIONAL IfcForceMeasure

Tension force in z-direction leading to failure of the connection.

5 CompressionFailureX OPTIONAL IfcForceMeasure

Compression force in x-direction leading to failure of the connection.

6 CompressionFailureY OPTIONAL IfcForceMeasure

Compression force in y-direction leading to failure of the connection.

7 CompressionFailureZ OPTIONAL IfcForceMeasure

Compression force in z-direction leading to failure of the connection.

Table 8.19.3.6.A

8.19.3.6.4 Formal representation

ENTITY IfcFailureConnectionCondition
 SUBTYPE OF (IfcStructuralConnectionCondition);
	TensionFailureX : OPTIONAL IfcForceMeasure;
	TensionFailureY : OPTIONAL IfcForceMeasure;
	TensionFailureZ : OPTIONAL IfcForceMeasure;
	CompressionFailureX : OPTIONAL IfcForceMeasure;
	CompressionFailureY : OPTIONAL IfcForceMeasure;
	CompressionFailureZ : OPTIONAL IfcForceMeasure;
END_ENTITY;

8.19.3.6.5 References

Edit on Github


Is this page difficult to understand? Let us know!