7.8.4.69 Pset_ElementAssemblyTypeTurnoutPanel
7.8.4.69.1 Semantic definition
Turnout panel properties used in railway. The property set can be used by the predefined type TURNOUT_PANEL of IfcElementAssembly.
7.8.4.69.2 Applicable entities
- IfcElementAssembly/TURNOUTPANEL
- IfcElementAssemblyType/TURNOUTPANEL
7.8.4.69.3 Properties
Name | Property Type | Data Type | Description | |
---|---|---|---|---|
IsAccessibleByVehicle | IfcPropertySingleValue | IfcBoolean |
Indicates whether the element is accessible by a vehicle or not. |
|
BranchLineDirection | IfcPropertyEnumeratedValue | PEnum_BranchLineDirection |
Describes the direction associated to the branch line of the turnout (deviated branch). |
|
TrackExpansion | IfcPropertyBoundedValue | IfcPositiveLengthMeasure |
In curvature context, bounded value of the expansion distance that can be added to rail gauge. |
|
TurnoutCurvedRadius | IfcPropertySingleValue | IfcLengthMeasure |
If turnout is curved, the main branch radius of curvature. |
|
TypeOfCurvedTurnout | IfcPropertyEnumeratedValue | PEnum_TypeOfCurvedTurnout |
Turnouts that are positioned in the curved part of the alignment. |
|
InstallationPlan | IfcPropertyReferenceValue | IfcDocumentReference |
Reference to external information source about installation or construction plan of the element. |
|
IsSharedTurnout | IfcPropertySingleValue | IfcBoolean |
Indicates if the turnout makes a connection to another infrastructure owner (for sharing costs). |
|
MaximumSpeedLimitOfDivergingLine | IfcPropertySingleValue | IfcLinearVelocityMeasure |
Maximum speed for diverging line that corresponds to the type of turnout and design constraints. |
|
TypeOfDrivingDevice | IfcPropertyEnumeratedValue | PEnum_TypeOfDrivingDevice |
Type of the driving device used for the turnout. |
|
TrackElementOrientation | IfcPropertyEnumeratedValue | PEnum_TurnoutPanelOrientation |
Turnout panels can be placed in 2 mirror-symmetric directions in the field. To distinguish both ends of the turnout panel, a definition of an orientation system with respect to the panel is necessary. The orientation defines, if the panel is oriented in a way or opposite with respect to the direction of the alignment/stationing. |
|
PercentShared | IfcPropertySingleValue | IfcPositiveRatioMeasure |
Percent of costs paid by the other infrastructure owner. |
|
TrackGaugeLength | IfcPropertySingleValue | IfcPositiveLengthMeasure |
Basic track gauge of permanent way. |
|
TurnoutPointMachineCount | IfcPropertySingleValue | IfcCountMeasure |
Count of point machines inside turnout panel. |
|
TurnoutHeaterType | IfcPropertyEnumeratedValue | PEnum_TurnoutHeaterType |
Defines the kind of turnout heater installed. |
|
TypeOfJunction | IfcPropertyEnumeratedValue | PEnum_TypeOfJunction |
The turnout part of the continuous welded rail. |
|
TypeOfTurnout | IfcPropertyEnumeratedValue | PEnum_TypeOfTurnout |
Type of turnout. |