7.5.4.76 Pset_PipeFittingTypeCommon
7.5.4.76.1 Semantic definition
Pipe fitting type common attributes.
7.5.4.76.2 Applicable entities
7.5.4.76.3 Properties
Name | Property Type | Data Type | Description | |
---|---|---|---|---|
Reference | IfcPropertySingleValue | IfcIdentifier |
Reference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used. |
|
Status | IfcPropertyEnumeratedValue | PEnum_ElementStatus |
Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure). |
|
PressureClass | IfcPropertySingleValue | IfcPressureMeasure |
Nominal pressure rating of the object. The test or rated pressure classification of the fitting. |
|
PressureRange | IfcPropertyBoundedValue | IfcPressureMeasure |
Allowable maximum and minimum working pressure (relative to ambient pressure). |
|
TemperatureRange | IfcPropertyBoundedValue | IfcThermodynamicTemperatureMeasure |
Allowable maximum and minimum temperature. |
|
FittingLossFactor | IfcPropertySingleValue | IfcReal |
A factor that determines the pressure loss due to friction through the fitting. |