IFC 4.3.2.20240904 (IFC4X3_ADD2) under development

7.8.4.46 Pset_DiscreteAccessoryTypeTensioningEquipment

7.8.4.46.1 Semantic definition

Properties of tensioning equipment used in railway. The property set can be used by the predefined type TENSIONINGEQUIPMENT of IfcDiscreteAccessory.

7.8.4.46.2 Applicable entities

7.8.4.46.3 Properties

Name Property Type Data Type Description
ReferenceEnvironmentTemperature IfcPropertyBoundedValue IfcThermodynamicTemperatureMeasure

Ideal temperature range.

AssemblyInstruction IfcPropertyReferenceValue IfcExternalReference

Instructions to describe how the system / equipment / facility is assembled.

HasBreakLineLock IfcPropertySingleValue IfcBoolean

Indicates whether the equipment has the function of brake line lock or not.

TensileStrength IfcPropertySingleValue IfcPressureMeasure

Indicates the ability to withstand breakage apart under applied force.

RatioOfWireTension IfcPropertySingleValue IfcPositiveRatioMeasure

The ratio of wire tension to tensioner weight.

TransmissionEfficiency IfcPropertySingleValue IfcRatioMeasure

Transmission efficiency of the tensioning equipment.

Table 7.8.4.46.A

Edit on Github


Is this page difficult to understand? Let us know!

7.8.4.46.4 Changelog

7.8.4.46.4.1 IFC4.3_DEV_c85b862

  • New resource