7.6.3.6 IfcSanitaryTerminalType
7.6.3.6.1 Semantic definition
The flow terminal type IfcSanitaryTerminalType defines commonly shared information for occurrences of sanitary terminals. The set of shared information may include:
- common properties with shared property sets
- common representations
- common materials
- common composition of elements
- common ports
It is used to define a sanitary terminal type specification indicating the specific product information that is common to all occurrences of that product type. The IfcSanitaryTerminalType may be declared within IfcProject or IfcProjectLibrary using IfcRelDeclares and may be exchanged with or without occurrences of the type. Occurrences of IfcSanitaryTerminalType are represented by instances of IfcSanitaryTerminal. Refer to the documentation at IfcSanitaryTerminal for supported property sets, materials, composition, and ports.
7.6.3.6.2 Entity inheritance
-
- IfcSanitaryTerminalType
- IfcAirTerminalType
- IfcAudioVisualApplianceType
- IfcCommunicationsApplianceType
- IfcElectricApplianceType
- IfcFireSuppressionTerminalType
- IfcLampType
- IfcLightFixtureType
- IfcLiquidTerminalType
- IfcMedicalDeviceType
- IfcMobileTelecommunicationsApplianceType
- IfcOutletType
- IfcSignalType
- IfcSpaceHeaterType
- IfcStackTerminalType
- IfcWasteTerminalType
7.6.3.6.3 Attributes
# | Attribute | Type | Description |
---|---|---|---|
IfcRoot (4) | |||
IfcObjectDefinition (7) | |||
IfcTypeObject (3) | |||
IfcTypeProduct (3) | |||
IfcElementType (1) | |||
Click to show 18 hidden inherited attributes Click to hide 18 inherited attributes | |||
IfcSanitaryTerminalType (1) | |||
10 | PredefinedType | IfcSanitaryTerminalTypeEnum |
Identifies the predefined types of sanitary terminal from which the type required may be set. |
7.6.3.6.4 Formal propositions
Name | Description | ||||
---|---|---|---|---|---|
CorrectPredefinedType |
No description available. |
||||
|
7.6.3.6.5 Property sets
-
Pset_Condition
- AssessmentDate
- AssessmentCondition
- AssessmentDescription
- AssessmentType
- AssessmentMethod
- LastAssessmentReport
- NextAssessmentDate
- AssessmentFrequency
-
Pset_ConstructionAdministration
- ProcurementMethod
- SpecificationSectionNumber
- SubmittalIdentifer
-
Pset_ElectricalDeviceCommon
- RatedCurrent
- RatedVoltage
- NominalFrequencyRange
- PowerFactor
- ConductorFunction
- NumberOfPoles
- HasProtectiveEarth
- InsulationStandardClass
- IP_Code
- IK_Code
- EarthingStyle
- HeatDissipation
- Power
- NominalPowerConsumption
- NumberOfPowerSupplyPorts
-
Pset_ElectricalDeviceCompliance
- ElectroMagneticStandardsCompliance
- ExplosiveAtmosphereStandardsCompliance
- FireProofingStandardsCompliance
- LightningProtectionStandardsCompliance
-
Pset_ElementKinematics
- CyclicPath
- CyclicRange
- LinearPath
- LinearRange
- MaximumAngularVelocity
- MaximumConstantSpeed
- MinimumTime
-
Pset_ElementSize
- NominalLength
- NominalWidth
- NominalHeight
-
Pset_EnergyRequirements
- EnergyConsumption
- PowerDemand
- EnergySourceLabel
- EnergyConversionEfficiency
-
Pset_EnvironmentalCondition
- ReferenceAirRelativeHumidity
- ReferenceEnvironmentTemperature
- MaximumAtmosphericPressure
- StorageTemperatureRange
- MaximumWindSpeed
- OperationalTemperatureRange
- MaximumRainIntensity
- SaltMistLevel
- SeismicResistance
- SmokeLevel
- MaximumSolarRadiation
-
Pset_EnvironmentalEmissions
- CarbonDioxideEmissions
- SulphurDioxideEmissions
- NitrogenOxidesEmissions
- ParticulateMatterEmissions
- NoiseEmissions
-
Pset_EnvironmentalImpactIndicators
- Reference
- FunctionalUnitReference
- IndicatorsUnit
- LifeCyclePhase
- ExpectedServiceLife
- TotalPrimaryEnergyConsumptionPerUnit
- WaterConsumptionPerUnit
- HazardousWastePerUnit
- NonHazardousWastePerUnit
- ClimateChangePerUnit
- AtmosphericAcidificationPerUnit
- RenewableEnergyConsumptionPerUnit
- NonRenewableEnergyConsumptionPerUnit
- ResourceDepletionPerUnit
- InertWastePerUnit
- RadioactiveWastePerUnit
- StratosphericOzoneLayerDestructionPerUnit
- PhotochemicalOzoneFormationPerUnit
- EutrophicationPerUnit
-
Pset_EnvironmentalImpactValues
- TotalPrimaryEnergyConsumption
- WaterConsumption
- HazardousWaste
- NonHazardousWaste
- ClimateChange
- AtmosphericAcidification
- RenewableEnergyConsumption
- NonRenewableEnergyConsumption
- ResourceDepletion
- InertWaste
- RadioactiveWaste
- StratosphericOzoneLayerDestruction
- PhotochemicalOzoneFormation
- Eutrophication
- LeadInTime
- Duration
- LeadOutTime
-
Pset_MaintenanceStrategy
- AssetCriticality
- AssetFrailty
- AssetPriority
- MonitoringType
- AccidentResponse
-
Pset_MaintenanceTriggerCondition
- ConditionTargetPerformance
- ConditionMaintenanceLevel
- ConditionReplacementLevel
- ConditionDisposalLevel
-
Pset_MaintenanceTriggerDuration
- DurationTargetPerformance
- DurationMaintenanceLevel
- DurationReplacementLevel
- DurationDisposalLevel
-
Pset_MaintenanceTriggerPerformance
- TargetPerformance
- PerformanceMaintenanceLevel
- ReplacementLevel
- DisposalLevel
-
Pset_ManufacturerTypeInformation
- GlobalTradeItemNumber
- ArticleNumber
- ModelReference
- ModelLabel
- Manufacturer
- ProductionYear
- AssemblyPlace
- OperationalDocument
- SafetyDocument
- PerformanceCertificate
-
Pset_Risk
- RiskName
- RiskType
- NatureOfRisk
- RiskAssessmentMethodology
- UnmitigatedRiskLikelihood
- UnmitigatedRiskConsequence
- UnmitigatedRiskSignificance
- MitigationPlanned
- MitigatedRiskLikelihood
- MitigatedRiskConsequence
- MitigatedRiskSignificance
- MitigationProposed
- AssociatedProduct
- AssociatedActivity
- AssociatedLocation
-
Pset_SanitaryTerminalTypeBath
BATH
- BathType
- DrainSize
- HasGrabHandles
-
Pset_SanitaryTerminalTypeBidet
BIDET
- Mounting
- SpilloverLevel
- DrainSize
-
Pset_SanitaryTerminalTypeCistern
CISTERN
- CisternHeight
- CisternCapacity
- IsSingleFlush
- FlushType
- FlushRate
- IsAutomaticFlush
-
Pset_SanitaryTerminalTypeCommon
- Reference
- Status
- NominalLength
- NominalWidth
- NominalDepth
- Colour
-
Pset_SanitaryTerminalTypeSanitaryFountain
SANITARYFOUNTAIN
- FountainType
- Mounting
- DrainSize
-
Pset_SanitaryTerminalTypeShower
SHOWER
- ShowerType
- HasTray
- ShowerHeadDescription
- DrainSize
-
Pset_SanitaryTerminalTypeSink
SINK
- SinkType
- Mounting
- Colour
- DrainSize
- MountingOffset
-
Pset_SanitaryTerminalTypeToiletPan
TOILETPAN
- ToiletType
- ToiletPanType
- PanMounting
- SpilloverLevel
-
Pset_SanitaryTerminalTypeUrinal
URINAL
- UrinalType
- Mounting
- SpilloverLevel
-
Pset_SanitaryTerminalTypeWashHandBasin
WASHHANDBASIN
- WashHandBasinType
- Mounting
- DrainSize
- MountingOffset
-
Pset_ServiceLife
- ServiceLifeDuration
- MeanTimeBetweenFailure
-
Pset_SoundGeneration
- SoundCurve
-
Pset_Tolerance
- ToleranceDescription
- ToleranceBasis
- OverallTolerance
- HorizontalTolerance
- OrthogonalTolerance
- VerticalTolerance
- PlanarFlatness
- HorizontalFlatness
- ElevationalFlatness
- SideFlatness
- OverallOrthogonality
- HorizontalOrthogonality
- OrthogonalOrthogonality
- VerticalOrthogonality
- OverallStraightness
- HorizontalStraightness
- OrthogonalStraightness
- VerticalStraightness
-
Pset_Uncertainty
- UncertaintyBasis
- UncertaintyDescription
- HorizontalUncertainty
- LinearUncertainty
- OrthogonalUncertainty
- VerticalUncertainty
-
Pset_Warranty
- WarrantyIdentifier
- WarrantyStartDate
- IsExtendedWarranty
- WarrantyPeriod
- WarrantyContent
- PointOfContact
- Exclusions
-
Qto_SanitaryTerminalBaseQuantities
- GrossWeight
7.6.3.6.6 Concept usage
Concept | Usage | Description | |
---|---|---|---|
IfcRoot (2) | |||
IfcObjectDefinition (9) | |||
IfcTypeObject (2) | |||
IfcTypeProduct (7) | |||
IfcElementType (5) | |||
IfcDistributionElementType (2) | |||
IfcDistributionFlowElementType (4) | |||
IfcFlowTerminalType (1) | |||
Click to show 32 hidden inherited concepts Click to hide 32 inherited concepts | |||
IfcSanitaryTerminalType (2) | |||
Property Sets for Objects | General |
This concept can be applied to the following resources:
|
|
Quantity Sets | General |
This concept can be applied to the following resources: |
7.6.3.6.7 Examples
7.6.3.6.8 Formal representation
ENTITY IfcSanitaryTerminalType SUBTYPE OF (IfcFlowTerminalType); PredefinedType : IfcSanitaryTerminalTypeEnum; WHERE CorrectPredefinedType : (PredefinedType <> IfcSanitaryTerminalTypeEnum.USERDEFINED) OR ((PredefinedType = IfcSanitaryTerminalTypeEnum.USERDEFINED) AND EXISTS (SELF\IfcElementType.ElementType)); END_ENTITY;