IFC 4.3.2.20250327 (IFC4X3_ADD2) under development

7.4.3.21 IfcElectricFlowTreatmentDevice

7.4.3.21.1 Semantic definition

An electric flow treatment device is used to remove unwanted matter from an electric or electronic signal in a flow distribution system.

7.4.3.21.2 Entity inheritance

7.4.3.21.3 Attributes

# Attribute Type Description
IfcRoot (4)
IfcObjectDefinition (7)
IfcObject (5)
IfcProduct (5)
IfcElement (13)
IfcDistributionElement (1)
IfcDistributionFlowElement (1)
Click to show 36 hidden inherited attributes
IfcElectricFlowTreatmentDevice (1)
9 PredefinedType OPTIONAL IfcElectricFlowTreatmentDeviceTypeEnum

A list of types to further identify the object. Some property sets may be specifically applicable to one of these types.

Table 7.4.3.21.D

7.4.3.21.4 Formal propositions

Name Description
CorrectPredefinedType

Either the PredefinedType attribute is unset(e.g. because an IfcElectricFlowTreatmentDeviceType is associated), or the inherited attribute ObjectType shall be provided, if the PredefinedType is set to USERDEFINED.

NOT(EXISTS(PredefinedType)) OR
(PredefinedType <> IfcElectricFlowTreatmentDeviceTypeEnum.USERDEFINED) OR
((PredefinedType = IfcElectricFlowTreatmentDeviceTypeEnum.USERDEFINED) AND EXISTS (SELF\IfcObject.ObjectType))
CorrectTypeAssigned

Either there is no type object associated, i.e. the IsTypedBy inverse relationship is not provided, or the associated type object has to be of type IfcElectricFlowTreatmentDeviceType.

(SIZEOF(IsTypedBy) = 0) OR
('IFC4X3_DEV_738df036.IFCELECTRICFLOWTREATMENTDEVICETYPE' IN TYPEOF(SELF\IfcObject.IsTypedBy[1].RelatingType))
Table 7.4.3.21.E

7.4.3.21.5 Property sets

  • Pset_Condition
    • AssessmentDate
    • AssessmentCondition
    • AssessmentDescription
    • AssessmentType
    • AssessmentMethod
    • LastAssessmentReport
    • NextAssessmentDate
    • AssessmentFrequency
  • Pset_ConstructionAdministration
    • ProcurementMethod
    • SpecificationSectionNumber
    • SubmittalIdentifer
  • Pset_ConstructionOccurence
    • InstallationDate
    • ModelNumber
    • TagNumber
    • AssetIdentifier
  • Pset_ElectricFlowTreatmentDeviceTypeElectronicFilter ELECTRONICFILTER
    • NominalPower
    • ElectronicFilterType
    • NominalCurrent
    • PrimaryFrequency
    • SecondaryFrequency
    • RatedVoltage
  • Pset_ElectricalDeviceCommon
    • RatedCurrent
    • RatedVoltage
    • NominalFrequencyRange
    • PowerFactor
    • ConductorFunction
    • NumberOfPoles
    • HasProtectiveEarth
    • InsulationStandardClass
    • IP_Code
    • IK_Code
    • EarthingStyle
    • HeatDissipation
    • Power
    • NominalPowerConsumption
    • NumberOfPowerSupplyPorts
  • Pset_ElectricalDeviceCompliance
    • ElectroMagneticStandardsCompliance
    • ExplosiveAtmosphereStandardsCompliance
    • FireProofingStandardsCompliance
    • LightningProtectionStandardsCompliance
  • Pset_ElementKinematics
    • CyclicPath
    • CyclicRange
    • LinearPath
    • LinearRange
    • MaximumAngularVelocity
    • MaximumConstantSpeed
    • MinimumTime
  • Pset_ElementSize
    • NominalLength
    • NominalWidth
    • NominalHeight
  • Pset_EnergyRequirements
    • EnergyConsumption
    • PowerDemand
    • EnergySourceLabel
    • EnergyConversionEfficiency
  • Pset_EnvironmentalCondition
    • ReferenceAirRelativeHumidity
    • ReferenceEnvironmentTemperature
    • MaximumAtmosphericPressure
    • StorageTemperatureRange
    • MaximumWindSpeed
    • OperationalTemperatureRange
    • MaximumRainIntensity
    • SaltMistLevel
    • SeismicResistance
    • SmokeLevel
    • MaximumSolarRadiation
  • Pset_EnvironmentalEmissions
    • CarbonDioxideEmissions
    • SulphurDioxideEmissions
    • NitrogenOxidesEmissions
    • ParticulateMatterEmissions
    • NoiseEmissions
  • Pset_EnvironmentalImpactIndicators
    • Reference
    • FunctionalUnitReference
    • IndicatorsUnit
    • LifeCyclePhase
    • ExpectedServiceLife
    • TotalPrimaryEnergyConsumptionPerUnit
    • WaterConsumptionPerUnit
    • HazardousWastePerUnit
    • NonHazardousWastePerUnit
    • ClimateChangePerUnit
    • AtmosphericAcidificationPerUnit
    • RenewableEnergyConsumptionPerUnit
    • NonRenewableEnergyConsumptionPerUnit
    • ResourceDepletionPerUnit
    • InertWastePerUnit
    • RadioactiveWastePerUnit
    • StratosphericOzoneLayerDestructionPerUnit
    • PhotochemicalOzoneFormationPerUnit
    • EutrophicationPerUnit
  • Pset_EnvironmentalImpactValues
    • TotalPrimaryEnergyConsumption
    • WaterConsumption
    • HazardousWaste
    • NonHazardousWaste
    • ClimateChange
    • AtmosphericAcidification
    • RenewableEnergyConsumption
    • NonRenewableEnergyConsumption
    • ResourceDepletion
    • InertWaste
    • RadioactiveWaste
    • StratosphericOzoneLayerDestruction
    • PhotochemicalOzoneFormation
    • Eutrophication
    • LeadInTime
    • Duration
    • LeadOutTime
  • Pset_InstallationOccurrence
    • InstallationDate
    • AcceptanceDate
    • PutIntoOperationDate
  • Pset_MaintenanceStrategy
    • AssetCriticality
    • AssetFrailty
    • AssetPriority
    • MonitoringType
    • AccidentResponse
  • Pset_MaintenanceTriggerCondition
    • ConditionTargetPerformance
    • ConditionMaintenanceLevel
    • ConditionReplacementLevel
    • ConditionDisposalLevel
  • Pset_MaintenanceTriggerDuration
    • DurationTargetPerformance
    • DurationMaintenanceLevel
    • DurationReplacementLevel
    • DurationDisposalLevel
  • Pset_MaintenanceTriggerPerformance
    • TargetPerformance
    • PerformanceMaintenanceLevel
    • ReplacementLevel
    • DisposalLevel
  • Pset_ManufacturerOccurrence
    • AcquisitionDate
    • BarCode
    • SerialNumber
    • BatchReference
    • AssemblyPlace
    • ManufacturingDate
  • Pset_ManufacturerTypeInformation
    • GlobalTradeItemNumber
    • ArticleNumber
    • ModelReference
    • ModelLabel
    • Manufacturer
    • ProductionYear
    • AssemblyPlace
    • OperationalDocument
    • SafetyDocument
    • PerformanceCertificate
  • Pset_RepairOccurrence
    • RepairContent
    • RepairDate
    • MeanTimeToRepair
  • Pset_Risk
    • RiskName
    • RiskType
    • NatureOfRisk
    • RiskAssessmentMethodology
    • UnmitigatedRiskLikelihood
    • UnmitigatedRiskConsequence
    • UnmitigatedRiskSignificance
    • MitigationPlanned
    • MitigatedRiskLikelihood
    • MitigatedRiskConsequence
    • MitigatedRiskSignificance
    • MitigationProposed
    • AssociatedProduct
    • AssociatedActivity
    • AssociatedLocation
  • Pset_ServiceLife
    • ServiceLifeDuration
    • MeanTimeBetweenFailure
  • Pset_SoundGeneration
    • SoundCurve
  • Pset_Tolerance
    • ToleranceDescription
    • ToleranceBasis
    • OverallTolerance
    • HorizontalTolerance
    • OrthogonalTolerance
    • VerticalTolerance
    • PlanarFlatness
    • HorizontalFlatness
    • ElevationalFlatness
    • SideFlatness
    • OverallOrthogonality
    • HorizontalOrthogonality
    • OrthogonalOrthogonality
    • VerticalOrthogonality
    • OverallStraightness
    • HorizontalStraightness
    • OrthogonalStraightness
    • VerticalStraightness
  • Pset_Uncertainty
    • UncertaintyBasis
    • UncertaintyDescription
    • HorizontalUncertainty
    • LinearUncertainty
    • OrthogonalUncertainty
    • VerticalUncertainty
  • Pset_Warranty
    • WarrantyIdentifier
    • WarrantyStartDate
    • IsExtendedWarranty
    • WarrantyPeriod
    • WarrantyContent
    • PointOfContact
    • Exclusions
  • Qto_BodyGeometryValidation
    • GrossSurfaceArea
    • NetSurfaceArea
    • GrossVolume
    • NetVolume
    • SurfaceGenusBeforeFeatures
    • SurfaceGenusAfterFeatures

7.4.3.21.6 Concept usage

Concept Usage Description
IfcRoot (2)
IfcObjectDefinition (9)
IfcObject (5)
IfcProduct (18)
IfcElement (44)
IfcDistributionElement (4)
IfcDistributionFlowElement (4)
IfcFlowTreatmentDevice (2)
Click to show 88 hidden inherited concepts
IfcElectricFlowTreatmentDevice (2)
Object Typing General

This concept can be applied to the following resources:

Property Sets for Objects General

This concept can be applied to the following resources:

Table 7.4.3.21.F

7.4.3.21.7 Formal representation

ENTITY IfcElectricFlowTreatmentDevice
SUBTYPE OF (IfcFlowTreatmentDevice);
PredefinedType : OPTIONAL IfcElectricFlowTreatmentDeviceTypeEnum;
WHERE
CorrectPredefinedType : NOT(EXISTS(PredefinedType)) OR
(PredefinedType <> IfcElectricFlowTreatmentDeviceTypeEnum.USERDEFINED) OR
((PredefinedType = IfcElectricFlowTreatmentDeviceTypeEnum.USERDEFINED) AND EXISTS (SELF\IfcObject.ObjectType));
CorrectTypeAssigned : (SIZEOF(IsTypedBy) = 0) OR
('IFC4X3_DEV_738df036.IFCELECTRICFLOWTREATMENTDEVICETYPE' IN TYPEOF(SELF\IfcObject.IsTypedBy[1].RelatingType));
END_ENTITY;

7.4.3.21.8 References

Edit on Github


Is this page difficult to understand? Let us know!

7.4.3.21.9 Changelog

7.4.3.21.9.1 IFC4.3_DEV_738df036

  • New resource